Rice-lake Counterpart Configurable Counting Indicator - User Manuale Utente

Navigare online o scaricare Manuale Utente per Bilance Rice-lake Counterpart Configurable Counting Indicator - User. Rice Lake Counterpart Configurable Counting Indicator - User Manual - Version 2.3 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 99
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
118677
Counterpart
Counting Scale Indicator
Version 2.3
User Manual
®
Vedere la pagina 0
1 2 3 4 5 6 ... 98 99

Sommario

Pagina 1 - User Manual

118677CounterpartCounting Scale IndicatorVersion 2.3User Manual®

Pagina 2

4 Counterpart User ManualFigure 1-1. Numeric Keypad1.5 Tare RecallWhen a stored tare is displayed, Net annunciators will be turned on. To display a st

Pagina 3 - Contents

Counterpart User Manual - Introduction 51.7 Softkey SetupSoftkeys offer additional ways to access features associated with the Counterpart. To access

Pagina 4

6 Counterpart User Manual2.0 InstallationCounterpart is available in different configurations from just the indicator display to the display and count

Pagina 5

Counterpart User Manual - Installation 72.2 Scale Base Assembly (if purchasing the scale base separate from indicator)CautionDo not turn the scale ups

Pagina 6 - 4 Counterpart User Manual

8 Counterpart User Manual2.3 Enclosure DisassemblyThe Counterpart indicator enclosure must be opened to connect cables for load cells, communications,

Pagina 7 - About This Manual

Counterpart User Manual - Installation 92.6 Wire Specifics Wires connecting to J1, J2, J3, or J4 should adhere to the following specifications:Table 2

Pagina 8 - 1.0 Introduction

10 Counterpart User ManualTable 2-3. J4 and J5 Pin AssignmentsNoteAn additional port (Port 3) is available if needed through the installation of an op

Pagina 9 - 1.4 Keypad Functions

Counterpart User Manual - Installation 112.8 Enclosure ReassemblyOnce the cabling is complete, position the top plate over the enclosure and reinstall

Pagina 10 - 1.6 Annunciator Symbols

12 Counterpart User Manual6. Using the supplied nuts, secure battery pack to enclosure using a 5/16” nut driver.Screw bracket into enclosure (only one

Pagina 11 - 1.9 Indicator Operations

Counterpart User Manual - Installation 135. Make connections to the option card as required. Use cable ties to secure loose cables inside the enclosur

Pagina 13

14 Counterpart User Manual2.12.1 USB Option Card InstallationUse the following steps to install the USB option card:1. Disconnect power cord from the

Pagina 14 - W arning

Counterpart User Manual - Installation 15bracket, otherwise it will not fit.Ensure the cable from the underside of the scale is run between bracket an

Pagina 15 - 2.6 Wire Specifics

16 Counterpart User Manual2.14 Indicator Replacement Parts and Assembly DrawingsRef Number Part Number Description (Quantity)1 118434 Overlay, Membran

Pagina 16 - 2.7.2Digital I/O

Counterpart User Manual - Installation 17Figure 2-16. Counterpart Assembly and Components

Pagina 17 - 2.9 CPU Board Removal

18 Counterpart User ManualFigure 2-17. Counterpart DimensionsFigure 2-18. Counterpart Rear and Side Dimensions

Pagina 18 - 2.12 Installing Option Cards

Counterpart User Manual - Configuration 193.0 Configuration3.1 Front Panel ConfigurationTo set up and configure the Counterpart counting Scale, you wi

Pagina 19 - Section 2.8

20 Counterpart User ManualVarious keys are used as directional keys to navigate through the menus (see Figure 3-2). The SAMPLE ( ) and PRINT ( ) keys

Pagina 20

Counterpart User Manual - Configuration 213.4 Audit MenuThe audit menu accesses audit trail support. It provides tracking information for configuratio

Pagina 21 - Ensure the cable from

22 Counterpart User Manual3.6 Setup MenuThe setup menu allows you to configure settings for the scale, features, serial port settings, Ethernet, print

Pagina 22

FEATUR ETHERNET PFORMTSERIAL DIGI/OXXXXXXXIDSC ACCUM DISPLAYTESTSETUPAUDIT CALIBRSCALESFORMATZRANGE MOTBANDOVRLOAD10000numberZTRKBND0number1.900000num

Pagina 23

Contents1.0 Introduction...

Pagina 24 - 18 Counterpart User Manual

24 Counterpart User ManualSETUP MenuParameter Choices DescriptionLevel 3 submenuSCALES 1 AND 2 Allows configuration and calibration of each scaleLevel

Pagina 25 - 3.2 Menu Navigation

Counterpart User Manual - Configuration 25DFSENS 4OUT2OUT8OUT16OUT32OUT64OUT128OUTDigital filter cutout sensitivity. Specifies the number of consecuti

Pagina 26 - 3.3 Revolution Configuration

26 Counterpart User ManualLevel 5 submenus - FormatPRIMRY UNITSDECPNTDSPDIVAllows you to set the primary units, decimal point format, and display divi

Pagina 27 - 3.4 Audit Menu

Counterpart User Manual - Configuration 273.6.2 SCALE 3 SubmenuFEATUR PFORMTSERIALXXXXXXXIDDISPLAYTESTSETUPAUDIT CALIBRSCALESFORMATACCUMOFFON SECUNIT

Pagina 28 - 3.6 Setup Menu

28 Counterpart User Manual3.6.3 FEATUR Submenu NEGCOUNTSAMPLQTY LOTUPDT1ONOFFCOUNTREGIONUIDCONSC#PASSWDSOFTKEYSKEYLCK1025SCALES FEATURECALIBRSETUPTEST

Pagina 29 - Scale Parameter Levels

Counterpart User Manual - Configuration 29 FEATUR MenuParameter Choices DescriptionLevel 3 submenus - FeatureCOUNT NEGCOUNTSAMPLEQTYINSFSMPLLOTUPDTSCL

Pagina 30 - SETUP Menu

30 Counterpart User ManualRECALL ONOFFON allows the Tare, Zero, and Units values to be maintained across a power cycle. Over/Under/Target/ID values ar

Pagina 31

Counterpart User Manual - Configuration 31DISPMODE COUNTWEIGHTUNITWEIGHTDisplay mode. This chooses the value to be displayed as large in viewing windo

Pagina 32

32 Counterpart User ManualCALIBR 0 Can enter a numeric password for each of the parameters listed. SETUPTESTT & DIDSPPWDLevel 4 submenus - under t

Pagina 33 - 3.6.2 SCALE 3 Submenu

Counterpart User Manual - Configuration 33Level 5 submenus - Under the Level 4 SCLCHG Feature REZERO OFFONPerforms a zero function on change.CHKSTBLE

Pagina 34 - Figure 3-8. FEATUR Submenu

2 Counterpart User Manual3.6.6 Setpoints Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 35 - UNITWTUPDATE

34 Counterpart User Manual3.6.4 FEATUR Menu, REGULA / INDUST SubmenuREGULATSNPSHTDISPLYINDUSTSCALENOYESZTARE KTAREYESNOMTAREREMOVEREPLACNOTHNNTAREYESN

Pagina 36 - FEATUR Menu

Counterpart User Manual - Configuration 35AGENCY NTEPCANADAINDUSTNONEOIMLSelects the agency having jurisdiction over the scale site.• OIML, NTEP, and

Pagina 37

36 Counterpart User Manual3.6.5 Serial, PFORMT, DIG I/O, VERS SubmenusSCALES FEATURPFORMTSOFTWRREGV 2.0LR, V.1.00See FEATURSubmenuSee SCALESubmenuDIO

Pagina 38

Counterpart User Manual - Configuration 37SETUP MenuParameter Choices DescriptionLevel 2 submenusSCALE See Section 3.6.1 on page 22 Configure scale se

Pagina 39

38 Counterpart User ManualOPTCARD NONEFIBERETHERNETWI-PORTRESERVEDUSBRS232-432KEYBOARDOption card parameters. Select which connection can be selected

Pagina 40

Counterpart User Manual - Configuration 39DIGIO OFFPRINTZEROTAREUNITSCLEARDSPACCNT/GRSCLRCNSAMPLESFTKEY1SFTKEY2SFTKEY3SFTKEY4OUTPUTDigital I/O functio

Pagina 41

40 Counterpart User Manual3.6.6 Setpoints MenuSCALES FEATURPFORMTXXXXXXXID DISPLAYTESTSETUPAUDIT CALIBRCONFIGVALUE SOURCETRIP BANDVALPREACTOFFIf TRIP=

Pagina 42 - COUNTERPART

Counterpart User Manual - Configuration 41Level 3 SubmenuSP CFG SETPT 1SETPT 2-6Specifies the settings for gross,net, piece count, % rel, delay, waits

Pagina 43

42 Counterpart User ManualWAITSS SourcePshaccmPhsprintPshtareAccessDigoutSenseCOUNTER ValueAccessDigoutINMOTION SourceAccessDigoutSenseLevel 6 Submenu

Pagina 44 - DFFLTGTWY

Counterpart User Manual - Configuration 43BATCH OffOnSpecifies whether the setpoint is used as a batch (ON) or continuous (OFF) setpoint.PSHACCM OffOn

Pagina 45

7.2.3 Using Revolution® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 46 - Figure 3-11. Setpoints Menu

44 Counterpart User ManualSetpoints Weigh Mode Parameter MenuSet up of setpoints is allowed while in the weigh mode. While setting up setpoints, the A

Pagina 47

Counterpart User Manual - Configuration 453.7 Calibration MenuSee Section 4.0 on page 49 for calibration procedures. The Calibration menu can be prote

Pagina 48

46 Counterpart User Manual3.8 Test MenuA/DDIG I/OCOMM KEYPADRAMLOOP DIO 1DIO 2 DIO 3STATUSDIO 4STATUSSTATUSSTATUSPORT1 PORT2TESTSPAN mVRAW ZEROVALVALV

Pagina 49

Counterpart User Manual - Configuration 473.9 Display MenuThere are three display settings on the Counterpart. CONTRASTXXXXXXXID DISPLAYTESTSETUPAUDIT

Pagina 50 - 44 Counterpart User Manual

48 Counterpart User ManualTable 3-11. ID Menu ParametersREG 1, 2 - 150QUANTITYCODEDESCPART NUMLOT UNIT WTTAREUNITSLOCATIONInventory quantity, range -

Pagina 51 - 3.7 Calibration Menu

Counterpart User Manual - Calibration 494.0 CalibrationThe Counterpart can be calibrated using the front panel, EDP commands, or Revolution®. NoteCali

Pagina 52

50 Counterpart User Manual4.2 Five-point linearizationFive-point linearization (using the WLIN parameter) provides increased scale accuracy by calibra

Pagina 53 - 3.10 ID Menu

Counterpart User Manual - Calibration 514.5 Revolution® CalibrationTo calibrate the indicator using Revolution, the indicator EDP port must be connect

Pagina 54

52 Counterpart User Manual5.0 Scale OperationsThe following paragraphs contain detailed operator instructions for Counterpart. Included are instructio

Pagina 55 - 4.0 Calibration

Counterpart User Manual - Scale Operations 535.3 Toggling Between Gross and NetTo toggle between net and gross weight, a tare value must be entered in

Pagina 57 - 4.6 More About Calibration

54 Counterpart User Manual5.4.1 Unit Weight Operation by SamplingUnit weight operation by sampling is accomplished by placing a 10 piece sample on the

Pagina 58 - 5.0 Scale Operations

Counterpart User Manual - Scale Operations 55Counting Out of a Full Container - See Total Amount Remaining in the ContainerTo carry out this operation

Pagina 59 - 5.4 Entering Unit Weights

56 Counterpart User Manual4. When you have reached the REG number you want to set, press to select that register number.5. Press and enter the CODE

Pagina 60

Counterpart User Manual - Scale Operations 575.5.4 Adding an ID From Count Mode1. Press the CODE softkey.2. Add in the ID number.3. If the ID number i

Pagina 61 - Figure 5-1. ID Menu

58 Counterpart User Manual5.6 WeighVaultWeighVault is a PC program which allows Counterpart users to add, edit, and access IDs over a network connecti

Pagina 62

Counterpart User Manual - Scale Operations 59Counterpart Setup for WeighVault1. On the Counterpart, enter configuration mode (see Section 3.0 on page

Pagina 63

60 Counterpart User Manual5.7 Totalization CountsCounterpart has a totalization function that allows you to totalize the quantity of several weighings

Pagina 64 - 5.6 WeighVault

Counterpart User Manual - Scale Operations 615.8 Parts Reduction CountsParts reduction can also be done by using the - key while the scale is in the w

Pagina 65 - 5.6.2 Using Weighvault

62 Counterpart User Manual5.10 Connecting a Barcode ScannerThe Counterpart will accept a barcode scanner connected to the unit. In order to use a scan

Pagina 66 - 5.7 Totalization Counts

Counterpart User Manual - Serial Commands 636.0 Serial CommandsThe Counterpart can be controlled by a PC or remote keyboard connected to an indicator

Pagina 67 - 5.8 Parts Reduction Counts

Counterpart User Manual - 1About This ManualThis manual is provided for the use of trained and qualified installers of counting scales, and represent

Pagina 68 - 62 Counterpart User Manual

64 Counterpart User Manual6.1.2 ID CommandsUp to 150 codes can be entered under ID commands.Command FunctionID.CODE#n ID code ID.DESC#n item descript

Pagina 69 - 6.0 Serial Commands

Counterpart User Manual - Serial Commands 656.1.5 Parameter Setting CommandsParameter setting commands allow you to display or change the current valu

Pagina 70

66 Counterpart User ManualSC.WLIN.V1SC.WLIN.V5#nTest weight value for linearization points 1–50.000001–9999999SC.WLIN.C1–SC.WLIN.C5#nCalibrate lineari

Pagina 71

Counterpart User Manual - Serial Commands 67OPTCARD Option cards NONE, FIBER, ETHERNET, WI-PORT, RESERVED, USB, RS232-422, KEYBOARDTable 6-6. FEATURE

Pagina 72

Table 6-8. DIG I/O Serial CommandsCommand Description ValuesDIO#b Digital I/O functionOFF, ZERO, NT/GRS, TARE, UNITS, PRINT, CLEAR, CLRCN, GROSS, DSPA

Pagina 73

Counterpart User Manual - Serial Commands 696.1.6 Normal Mode CommandsThe normal mode print commands (see Table 6-12) transmit data to the serial port

Pagina 74

70 Counterpart User Manual7.0 Print FormattingThe Counterpart provides nine print formats, GFMT, NFMT, TOTALFMT, PALFMT, CFMT, ACCFMT, SPFMT, HDRFMT1,

Pagina 75 - Table 6-13. Unique Commands

Counterpart User Manual - Print Formatting 71Command DescriptionSupported Ticket Formats<G> Gross weight, current scale GFMT, NFMT, TOTALFMT, PA

Pagina 76 - 7.0 Print Formatting

72 Counterpart User Manual<SCV> Setpoint captured weight valueSPFMT<SN> Setpoint weight number<STV> Setpoint target weightvalue<S

Pagina 77 - Supported Ticket

Counterpart User Manual - Print Formatting 73The 500-character limit of each print format string includes the output field length of the print formatt

Pagina 78

2 Counterpart User Manual1.0 IntroductionThe Counterpart offers practical solutions for a full range of precision counting applications. A bright LCD

Pagina 79 - 7.2 Customizing Print Formats

74 Counterpart User Manual7.2.2 Using the Front PanelIf you have no access to equipment for communication through the EDP port or are working at a sit

Pagina 80 - Format Format

Counterpart User Manual - Print Formatting 757.2.4 Print Label ExamplesListed below are print formatting examples (using the default formats) that app

Pagina 81

76 Counterpart User ManualTotal Label FormatFigure 7-7. Total Format Label ExampleGross/Tare/Net Label FormatFigure 7-8. Gross/Tare/Net Label FormatAc

Pagina 82 - 76 Counterpart User Manual

Counterpart User Manual - WLAN Installation Instructions 778.0 WLAN Installation InstructionsNoteBefore installing this option, you must contact your

Pagina 83

78 Counterpart User Manual9.0 Appendix9.1 Error MessagesIf an error code appears on the display, use the information in Table 9-1 as a troubleshooting

Pagina 84 - - - - - -

XE Error Code (decimal) Description XEH Error Code (hexadecimal)1 VIRGERR 0x000000012 PARMCHKERR 0x000000024 LOADCHKERR 0x000000048 PRINTCHKERR 0x0000

Pagina 85 - 9.2.1 Using the P EDP Command

80 Counterpart User Manual9.3 Continuous Output (Stream) FormatFigure 9-1 shows the default continuous output format sent to a Counterpart port when t

Pagina 86 - 9.5 Custom Stream Formatting

Counterpart User Manual - For More Information 81<B [–]n,…> See descriptions below Bit fields. Comma-separated sequence of bit field specifiers.

Pagina 87

82 Counterpart User ManualB18 Configuration =000 if primary DECPNT=8888800=001 if primary DECPNT=8888880=010 if primary DECPNT=8888888=011 if primary

Pagina 88

Counterpart User Manual - For More Information 839.6 Digital FilteringThe Counterpart uses averaged digital filtering to reduce the effect of vibratio

Pagina 89 - 9.6 Digital Filtering

Counterpart User Manual - Introduction 31.4 Keypad Functions Table 1-2. Keypad Functions Key Function POWERTurns the Counterpart unit on/off.NO

Pagina 90 - 9.7 USB Keyboard Interface

84 Counterpart User Manual2. Remove all weight from the scale, then watch the indicator display to determine the magnitude of vibration effects on the

Pagina 91 - 9.8 Serial Scale Interface

Counterpart User Manual - For More Information 859.8 Serial Scale InterfaceSerial port 1 can be configured for serial scale input. The serial scale fu

Pagina 92 - 9.9 Regulatory Mode Functions

86 Counterpart User Manual9.9 Regulatory Mode FunctionsThe function of the front panel TARE and ZERO keys depends on the value specified for the REGUL

Pagina 93

Counterpart User Manual - For More Information 879.10 Regulatory Mode and Legal-for-Trade (LFT)NoteWhen REGULAT is set for NONE or INDUST there are no

Pagina 94 - 88 Counterpart User Manual

88 Counterpart User Manual9.10.2 Legal-for-Trade and Totalization ModeWhen in Legal-for-Trade mode (REGULAT = NTEP, OIML, or CANADA) and the unit is i

Pagina 95 - 9.11 Updating Firmware

Counterpart User Manual - For More Information 899.11 Updating FirmwareTo update firmware of the Counterpart, you must have Revolution installed and a

Pagina 96 - 9.12 Specifications

90 Counterpart User ManualFigure 9-5. Rice Lake Updater Screen8. Click the Program button. The update will take several moments. 9. When complete, rem

Pagina 97 - 9.13 Specifications

Counterpart User Manual - For More Information 919.13 SpecificationsPOWER:Power source:Input: 100-240VAC, 47-63 Hz, 5 watts, US power cordOutpu

Pagina 98 - Counterpart Limited Warranty

92 Counterpart User ManualCounterpart Limited WarrantyRice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installe

Pagina 99 - For More Information

Counterpart User Manual - For More Information 93For More InformationLiterature• Counterpart Sales Literature, PN 125545• Counterpart CD with WeighVau

Commenti su questo manuale

Nessun commento